BD Sensors 18.601G-6000-R-3-5-100-300-1-000
Input pressure range
Nominal pressure gauge [bar] 0.1 0.16 0.25 0.4 0.6 1 1.6 2.5 4 6
Overpressure [bar] 1 1 1 1 3 3 6 10 10 21
Burst pressure ≥ [bar] 1.5 1.5 1.5 1.5 5 5 10 17.5 17.5 35 Vacuum resistance unlimited
Output signal / Supply
Standard 2-wire: 4 ... 20 mA / VS = 8 ... 32 VDC
Options 3-wire 3-wire: 0 ... 10 V / VS = 14 ... 30 VDC 3-wire ratiometric: 10 ... 90 % of VS / VS = 2.7 ... 5 VDC
Performance
Accuracy pN > 160 mbar: ≤ ± 0.5 % FSO pN ≤ 160 mbar: ≤ ± 1 % FSO
Permissible load 2-wire: Rmax = [(VS – VS min) / 0.02 A] Ω 3-wire: Rmin = 10 kΩ
Influence effects supply: 0.05 % FSO / 10 V load: 0.05 % FSO / kΩ
Response time 2-wire: ≤ 10 msec 3-wire: ≤ 3 msec
Long term stability ≤ ± 0,2 % FSO / year at reference conditions
Measuring rate 1 kHz 1
accuracy according to IEC 61298-2 – limit point adjustment (non-linearity, hysteresis, repeatability)
Thermal effects (offset and span) / Permissible temperatures
Thermal error ≤ ± 0.3 % FSO / 10 K in compensated range 0 ... 70 °C
Permissible temperatures medium: -25 … 125 °C electronics / environment: -25 ... 85 °C storage: -40 ... 85 °C
Electrical protection
Short-circuit protection permanent 3-wire ratiometric: none
Reverse polarity protection no damage, but also no function
Electromagnetic compatibility emission and immunity according to EN 61326
Mechanical stability
Vibration 20 g RMS / 10 … 2000 Hz according to DIN EN 60068-2-6
Shock 500 g / 1 msec half sine according to DIN EN 60068-2-27
Frequently Bought Together
Products from this Seller
View All
Share with Friends
Trading is more effective when you share products with friends!Share you link
Share to